cavity shaftwall systems national gypsum

  • USG SHAFT WALL SYSTEMSBuildSite

    USG Shaft Wall Systems are non-load-bearing gypsum wall partition asse mblies constructed from outside the shaft at each loor. Shafts are enclosed early in construct ion and the walls are inished later along with interior partitions. Installation is quick and ea sy using components and application procedures familiar to drywall contractors.

    Chat Online
  • WARE s NEW Shaftwall and Area Separation Wall Systems

    1" gypsum liner board ANYUL Classified 1/2"Type C or 5/8"Type X gypsum wallboard Both the MARINOWARE CT-Stud Shaftwall and H-Stud Area Separation Wall Systems are approved with all UL-listed gypsum board manufacturers including United States Gypsum National Gypsum Georgia-Pacific Lafarge Gypsum James Hardie BPB PABCO Temple Eagle

    Chat Online
  • Cavity Shaftwall Systems on Designer Pages

    For information on system requirements contact National Gypsum s Technical Service at 1-800-NATIONAL® (1-800-628-4662). Features Benefits Although the Cavity Shaftwall system is nonload-bearing this system has been designed and tested to withstand positive and negative air pressure forces exerted by high-speed high-rise elevators.

    Chat Online
  • National Gypsum Gold Bond Fire-Shield Shaftliner XP

    The panels are key components in the I-Stud Cavity Shaftwall System and the H-Stud Area Separation Wall System. Circle . 125. In My Own Words "Whenever we build multi-family homes we always use National Gypsum 1-Inch Gold Bond Shaftliner XP because it is a fire shield and is mold- and moisture-resistant. The latter features are key.

    Chat Online
  • ShaftWall is a Fire resistant shaft and duct encasement system

    ShaftWall Shaft and duct encasement system. ShaftWall provides a lightweight fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an

    Chat Online
  • 1 in x 2 ft x 12 ft National Gypsum Gold Bond BRAND eXP

    Gold Bond® BRAND eXP® Shaftliner is a moisture and mold resistant shaftliner panel with a fire-resistant Type X core. eXP Shaftliner is manuf

    Chat Online
  • cavity shaftwall systems national gypsum

    138 cavity shaftwall systems section 09 21 16.23 shaftwall systems the following paragraphs are for insertion into sections of generic specifications or generic/proprietary specifications covering shaftwall products.the national gypsum company product name follows the generic description in parentheses.

    Chat Online
  • Allied Building Products Drywall Accessories > National

    The panels are key compo-nents in the C-H C-T I-Stud Cavity Shaftwall System and the H-Stud Area Separation Wall System. Accessories. NATIONAL GYPSUM 5/8INCH 4X10 FIRE CODE XP. National Gypsum. J TRACK 4IN 10FT 20GA TABBED. ClarkWestern Building Systems

    Chat Online
  • Specialty Metal Solutions FIRETRAK Deflection Track

    The Fire Trak System does not require fire caulk or spray to achieve a fire rating. This allows the Fire Trak System substantially greater movement capabilities than other systems. The Fire Trak System achieves a full 100 compression and/or extension and has been tested and listed with U.L. for deflection up to 6".

    Chat Online
  • Horizontal Shaftwall Duct and Ceiling Assemblies 09 21 16

    136 cavity shaftwall systems section 09 21 16.23 shaftwall systems the following paragraphs are for insertion into sections of generic specifications or generic/proprietary specifications covering shaftwall products.the national gypsum company product name follows the generic description in parentheses.

    Chat Online
  • PABCO GLASS® Shaftliner PABCO Gypsum

    Cavity Shaftwall Systems componentlight weight fire barrier for cavity shaft walls Extended exposure to normal weather conditions up to 1 year during construction Part of the PABCO GLASS® family PABCO GLASS® SHAFTLINER protects your building from fire mold and water in a Shaftliner format.

    Chat Online
  • ClarkDietrich Shaftwall Systems ClarkDietrich Building

    ClarkDietrich Building Systems provides fully tested and approved assemblies for shaftwall construction. What makes the ClarkDietrich system unique is that it has been tested with almost every gypsum board and shaft liner manufacturer in the country. Unlike competing systems the ClarkDietrich CT Stud and J-Tabbed Track system provide maximum flexibility to choose from a

    Chat Online
  • Submittal Sheet Shaftwall Insulation

    in the cavity of a metal stud and gypsum board shaftwall partition system. Shaftwall Insulation reduces the amount of airborne sound transmitted through the shaftwall to the adjoining space. Depending on the construction method used Shaftwall Insulation can reduce the amount of airborne sound transmitted through a shaftwall by as much as 5 to

    Chat Online
  • AER-09038 Page 1 of 10

    Page 3 of 10 Two-Hour Stair Cavity Shaftwall (Non-Load Bearing) See Figure 3 4. 1" thick SHEETROCK® Brand Gypsum Liner PanelFriction-fitted in "H" portion of C-H studs. Three-Hour Cavity Shaft Wall (Non-Load Bearing) See Figure 4 1. A minimum 2-/12" deep 25 gauge floor and ceiling J-runners attached to the structure as described in the Figure 4.

    Chat Online
  • Allied Building Products Drywall Accessories > National

    The panels are key compo-nents in the C-H C-T I-Stud Cavity Shaftwall System and the H-Stud Area Separation Wall System. Accessories. NATIONAL GYPSUM 5/8INCH 4X10 FIRE CODE XP. National Gypsum. J TRACK 4IN 10FT 20GA TABBED. ClarkWestern Building Systems

    Chat Online
  • CertainTeed Shaftliner for Gypsum Shaftwall Systems 1 2

    ProRoc® Brand Shaftliner for Gypsum Shaftwall™ Systems • Call Toll Free 1-800-233-8990 • certainteed5 10. Frame all cut openings in the shaft side with J-Track providing adequate structural support for openings over 48". 11. Elevator door frames must be tied to shaftwall

    Chat Online
  • The place to stopbefore the building starts SM

    System consists of 1" shaftliner panels supported by 2-1/2" 4" or 6" CT-Studs and faced on one side with two layers of 1/2" proprietary fire code board. Shaftwall Designed to enclose stairwalls this system is finished on both sides with a single layer of 1/2" proprietary fire code board. Stairwall DMF C-T Stud Nominal Design Weight Areas lx

    Chat Online
  • ProductProgressive Engineering Inc

    7. Gypsum fasteners thru gypsum into framing. 8. Approved Fire-Resistance joint sealant system. See ClarkDietrich Horizontal Shaftwall Assembly Instructions for more details. Page 6 of 8 Figure 3Two (2) Hour Assembly Figure 4C-T Stud to J-Runner Connection AER-12061 L / 120 L / 180 L / 240 L / 360 L / 120 L / 180 L / 240 L / 360

    Chat Online
  • AECinfo News National Gypsum Debuts Newest Purple

    Apr 19 2009 · National Gypsum today introduced the building community to its newest purple choice e 2 XP Extended Exposure Shaftliner at the Association of the Wall and Ceiling Industry (AWCI) Convention and INTEX EXPO 2009 in Nashville.. e 2 XP Extended Exposure Shaftliner is the primary component of Cavity Shaftwall Systems that are designed to enclose elevator shafts stairwells and

    Chat Online
  • Horizontal Shaftwall and Duct Protection on Designer Pages

    Note Horizontal Shaftwall and Duct Protection Systems have been tested as complete assemblies. Substitution of components may adversely affect system performance. For information on system requirements contact National Gypsum s Technical Services at 1-800-National® (1-800-628-4662).

    Chat Online
  • Shaftwall History AWCI s Construction Dimensions AWCI

    The first project was an office building in Los Angeles. This project was followed by a gypsum partition shaft wall application at the Central National Bank Building in Cleveland and then at the U.S. Steel Building in Pittsburgh. Designers today have much more flexibility in both cavity shaft wall material selection and system design.

    Chat Online
  • USG SHAFT WALL SYSTEMSBuildSite

    USG Shaft Wall Systems are non-load-bearing gypsum wall partition asse mblies constructed from outside the shaft at each loor. Shafts are enclosed early in construct ion and the walls are inished later along with interior partitions. Installation is quick and ea sy using components and application procedures familiar to drywall contractors.

    Chat Online
  • Cavity Shaftwall SystemsNational Gypsum

    The Cavity Shaftwall Systems were developed to enclose elevator shafts and other vertical chases in buildings where it is advantageous to erect these walls from one side only and where fire resistance and resistance to air pressures are required. National Gypsum Company Cavity Shaftwall Systems may be constructed with C-T C-H or I-Stud

    Chat Online
  • FIRE-SHIELD SHAFTLINER XP (National Gypsum) Free BIM

    The panels are key components in the I-Stud C-T Stud and C-H Stud Cavity Shaftwall Systems and the H-Stud Area Separation Fire Wall Systems. Shaftliner XP is designed to provide extra protection against mold and mildew compared to standard Shaftliner products. Shaftliner XP is easily identified by National Gypsum s original PURPLE™ color.

    Chat Online
  • Cavity Shaft Wall SystemUSG

    USG Cavity Shaft Wall can be used in elevator and mechanical shafts air ducts stairwells and areas where wall construction is only available from one side. In addition USG Cavity Shaft Wall can be used to provide horizontal protection for corridor ceilings underside of stairwells and other applications.

    Chat Online
  • Design No. U429SCAFCO

    NATIONAL GYPSUM CO — Types FSW FSW­B FSW­7 FSW­9 PABCO BUILDING PRODUCTS L L C DBA PABCO GYPSUM — Types PG­10 and PG­10G THAI GYPSUM PRODUCTS PCL — Type Shaftliner 4. Gypsum Board — 1/2 or 5/8 in. thick 4 ft wide applied vertically and attached to

    Chat Online
  • USG Boral Hotel Building Products Systems

    ELEVATOR SERVICE SHAFTWALL SYSTEM. Achieve high acoustical and minimise vibrations from lift machinery that can cause disturbances to your guest s hotel stay. (Acoustic performance is up to STC 52.) 12 hrs Shaftwall System. FIRE RESISTANT SYSTEM

    Chat Online
  • NATIONAL GYPSUM COMPANY Cavity Shaftwall

    Cavity Shaftwall Systems Cavity Shaftwall Systems Installation description The cavity shaftwall system consists of steel C-T C-H or I-Studs and J-Tracks with 1 in. (25.4 mm) shaftliner panels friction fit between the studs. Single or multiple layers of Gold Bond® brand Fire-Shield® Gypsum Board are applied to the face of the studs to

    Chat Online
  • CertainTeed Shaftliner for Gypsum Shaftwall Systems 1 2

    ProRoc® Brand Shaftliner for Gypsum Shaftwall™ Systems • Call Toll Free 1-800-233-8990 • certainteed5 10. Frame all cut openings in the shaft side with J-Track providing adequate structural support for openings over 48". 11. Elevator door frames must be tied to shaftwall

    Chat Online
  • Technical Services 888-437-3244 Sales 800-543-7140

    ClarkDietrich CT Cavity Shaftwall System ClarkDietrich CT Cavity Shaftwall Studs are high-performance members engineered to maintain shaftwall integrity. CT Studs are designed for use with 1" thick gypsum 24" wide liner panels. Gypsum liner panels are inserted into the "T" portion of the stud and are friction fit. The system is

    Chat Online
  • ShaftWallBritish Gypsum

    ShaftWall (C05 S02) Shaft and duct encasement system. ShaftWall provides a lightweight fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding.

    Chat Online
  • cavity shaftwall systems national gypsum

    138 cavity shaftwall systems section 09 21 16.23 shaftwall systems the following paragraphs are for insertion into sections of generic specifications or generic/proprietary specifications covering shaftwall products.the national gypsum company product name follows the generic description in parentheses.

    Chat Online
  • Section 09 29 00Gypsum BoardDesign Construction

    System Georgia-Pacific Gypsum LLC s "Series 627 (Two Hour) Shaftwall System" National Gypsum Co. s "Gold Bond I-Stud Cavity Shaftwall System" or equal. Fire Rating Two hours. Metal Components J-runners C-channels and C-H studs hot-dip galvanized steel sizes and types as recommended by system manufacturer.

    Chat Online
  • Cavity Shaftwall Systems on Designer Pages

    For information on system requirements contact National Gypsum s Technical Service at 1-800-NATIONAL® (1-800-628-4662). Features Benefits Although the Cavity Shaftwall system is nonload-bearing this system has been designed and tested to withstand positive and negative air pressure forces exerted by high-speed high-rise elevators.

    Chat Online
  • H-Stud Area Separation Wall SystemAmerican Gypsum

    3. The gypsum board can be dried thoroughly before mold growth begins (typically 24 to 48 hours depending on environmental conditions). 4. The gypsum board is structurally sound and there is no evidence of rusting fasteners or physical damage that would diminish the physical properties of the gypsum board or system.

    Chat Online
  • What You Should Know About Cavity Shaftwalls National Gypsum

    Yes National Gypsum has several options for rated horizontal systems 2-hour rated UL Design G586 or 1- and 2-hour horizontal shaftwall assemblies per UL Evaluation Report ER R3501-02 (Section 6.3.1). These are typical horizontal assemblies used in a fire-rated corridor.

    Chat Online